Model
6500
Head
Space Analyzer |
The
Model
6500 Head Space Analyzer offered by Illinois uses just two-button
operation for simple, accurate measurements of head space in packaged product.
The head space analyzer is used in the food and pharmaceutical industries
to measure the head space for oxygen content from 0% to 100%. A perfect
fit for both production and laboratory environments, the Model 6500 Oxygen
Head Space Analyzer uses just one-touch analysis. The head space
analyzer can also be calibrated to ambient air using a single button
Simply insert the needle into the package
and press analyze on the head space analyzer. The pump inside the
head space analyzer turns on, takes a sample, and displays the reading
within a few seconds.
Use the menu above to request more information
regarding our head space analyzer, our permeation analyzers, or our permeation
testing service.
Illinois Instruments'
model 6500 Head Space Analyzer
measures trace oxygen within packaging headspace. The Model 6500 offers
new levels of performance, technology and operator ease to fulfill the
latest industry demands for accuracy and reliability.
This
highly advanced instrument is equipped with an integral sampling systems,
a unique miniature zirconia sensor, and microprocessor control to deliver
the most accurate and repeatable performance possible.
One
touch automated calibration and product analysis make these analyzers easy
to use.
Rugged
and compact epoxy clad cabinetry, seamless operator's console and no-compromise
engineering place these instruments at home in both the laboratory or the
demanding climate of the production floor.
Automated
package sampling is easy. Just insert the sampling needle into the package
and press analyze. The instrument does the rest: extracting the sample,
analyzing sensor output and holding the results for viewing on the bright
autoranging display.
Headspace
samples may be injected directly into the instrument when automated sampling
is not practical.
Versatile
accessory sampling system is perfect for rigid packaging and has proven
rugged and reliable in hundreds of demanding application.
All
6000 Series Analyzers include these Special Features:
A.
Precision flowmeter provides visual confirmation
of sample flow. Unlike warning lights, users can monitor system performance
and resolve potential problems before they occur.
B.
Convenient wand holder is easy to use
and helps prevent needle contamination and sample line damage.
C.
Display hold locks most recent high or
low concentration value. Bright, large character display is easy to read
in any lighting condition. Status lights indicate mode of operation.
D.
Auto calibration
is simple. With a single button the instrument self calibrates in just
30 seconds using ambient air.
E.
Timed, automatic analysis is provided
at the touch of a button. Programmable sampling duration and data integration
make these among the most advanced headspace analyzers available.
F.
RS232 output prints product description
and sample data to 40 column printer for hard copy of calibration and test
results. Prints test "Fail" according to user defined alarm settings.
G.
Unique sensors allow analysis of small
sample volumes. Response is typically less than five seconds for oxygen
and ten seconds for carbon dioxide. Internal microprocessor manages calibration,
autoranging, pump speed and duration, time and date, outputs, and many
other functions to ensure consistent, error-free results.
H.
Rugged sample wand is designed to accept
standard luer accessories and includes easily replaced needles and particulate
filters.
Compact
enclosure maximizes space on carts and
table tops. Seamless cover design and polycarbonate operator's panel sheds
spills and resists most chemicals and solvents.
User
friendly software parameters are easy
to enter and can be secured against accidental change. |