Series
500
Moisture
Permeation Analyser |
Illinois
Instruments offers a Moisture Permeation Analyser for almost
any application where trace moisture is measured in a gas stream.
The Series 400 Moisture Permeation Analyser
and Series 500 Moisture Permeation Analyser
offer different sensor technologies to meet your specific requirements.
The Series 500 Moisture Permeation Analyser uses a phosphorus pentoxide
(P2O5) sensor for measuring moisture from 0 to 1000ppm. The Series
400 Moisture Permeation Analyser uses an aluminum oxide (Al2O3) sensor
t to measure moisture from -90oC to +20oC in most industrial gas streams.
The Moisture Permeation Analyser can be
configured in a variety of ways to suit your specific application.
It is available as a benchtop/panel mountable cabinet, a NEMA 4X wall mount
cabinet, or in a 19 inch rack mountable cabinet.
The 500 Moisture Permeation Analyser can
have an integral sensor or use a remote mounted sensor in general purpose
areas. The 400 Moisture Permeation Analyser can be equipped with
an integral sensor, or you can have a remote mounted sensor for either
general purpose or hazardous areas.
Illinois Instruments'
Series 500 Moisture Permeation Analyser
represents our latest advancement in moisture analysis. This series was
designed to be customized to your application while providing a simple,
yet affordable analyzer. The Series 500 Moisture Analyser
incorporates microprocessor control with our high quality electrolytic
moisture sensor to bring flexibility to your process environment. These
analyser provides accurate depend-able results over a wide range from 0.1
ppm to 1000 ppm.
All
models feature microprocessor control for stable and repeatable operation.
A bright, autoranging LED display provides direct measurement output. User-adjustable
alarms, scaleable analog output signals, RS232 interfacing, and process
sample bypass flow systems are all optionally available.
Three
different configurations add to the base Model
510 to offer the choices needed to satisfy
virtually all industrial environment and operational constraints.
 |
 |
 |
Model
510
can be
used on the bench
or
Panel Mounted. |
Model
520
is NEMA
4X / IP66
rated
for weatherproof
and
waterproof locations. |
Model
530
houses
one or two analysers
in
its 4U (19 inch)
rack
mount cabinet.
|
Features:
|
|
Autoranging
from 0.1 to 1000 ppm |
|
|
RS232/485
outputs |
|
|
ppmv,
°C, and °F units |
|
|
No
calibration required |
|
|
Remote
sensors available |
Applications:
|
|
Heat
Treating Furnaces |
|
|
Air
Dryers |
|
|
Compressed
Air |
|
|
Metallurgy |
|
|
Chemical
Manufacturing |
|
|
Plastics
Manufacturing |
|
|
Inert
Atmosphere Blanketing |
|